Page 171 - Template Tesis UTM v2.0
P. 171
hence will damage the fibre. On the other hand, [G/F]3G created minor ply splitting as
depicted in Figure 4.30(b). These kind of failure images possible to describe the
weakness of [G/B]3G and [G/F]3G in resisting impact loading in comparison with
G2/B3/G2 and G2/F3/G2. However, E-glass/flax recorded the highest specific energy
absorption than the other hybrid composites. The advantages of this combination can
be clearly seen with minor surface cracks or damages as illustrated in Figure 4.31. As
a result, it can be concluded that the formation of hybrid composite between E-glass
and flax fibres with epoxy resin shows a good surficial adhesion and it would
potentially to be used in composite industry.
Front Back
Figure 4.29 Fractographs of [G/J]3G after impact loading
(a) (b)
Figure 4.30 Fractographs of ; (a) [G/B]3G, and (b) [G/F]3G on the back surface after
impact loading
140