Continuous Cooler





 a. Air cooled                                       b. Water cooled



 This type of aftercooler uses air to cool down the   1. This type of aftercooler uses water to cool down the hot air
 compressed air. This air cooled aftercooer consists   after compression. The arrangement of the air inlet, air outlet,
 nest of tubes as shown in figure (a). Hot air enters the   water inlet and water outlet are as shown in the figure (b).
 aftercooler through inlet and passes by the nest of   2. The flow of water and air should be opposite direction through
 tubes. The air will be cooled down by means of cold air   the cooler. Temperature of the air discharged should be
 produced by fan assembled in the aftercooler.  approximately 10°C above the temperature of the cooling
 water. The accumulated condensation is removed through an
 automatic drain, attached to aftercooler. Usually, aftercoolers
 equipped with a safety valve, pressure gauge, and
 thermometer pockets for air and water.





 a. Principle of an air cooled aftercooler


 Click here to watch
 a.  Air cooled cooler  b. Principle of a water cooled aftercooler

 b.  Water cooled cooler