Page 55 - Pneumatic ebook (2)_draft 13 sept 2021
P. 55

Continuous Cooler





                                      a. Air cooled                                                                          b. Water cooled



    This type of aftercooler uses air to cool down the               1. This type of aftercooler uses water to cool down the hot air
    compressed air. This air cooled aftercooer consists                  after compression. The arrangement of the air inlet, air outlet,
    nest of tubes as shown in figure (a). Hot air enters the             water inlet and water outlet are as shown in the figure (b).
    aftercooler through inlet and passes by the nest of              2. The flow of water and air should be opposite direction through
    tubes. The air will be cooled down by means of cold air              the cooler. Temperature of the air discharged should be
    produced by fan assembled in the aftercooler.                        approximately 10°C above the temperature of the cooling
                                                                         water. The accumulated condensation is removed through an
                                                                         automatic drain, attached to aftercooler. Usually, aftercoolers
                                                                         equipped with a safety valve, pressure gauge, and
                                                                         thermometer pockets for air and water.





             a. Principle of an air cooled aftercooler


                                         Click here to watch
                                         a.  Air cooled cooler                       b. Principle of a water cooled aftercooler

                                         b.  Water cooled cooler

                                                               INTRODUCTION TO PNEUMATIC SYSTEM                                            23