Page 48 - Williams Hematology ( PDFDrive )
P. 48

24             Part I:  Clinical Evaluation of the Patient                                                                                                                        Chapter 2:  Examination of Blood Cells            25




               REFERENCES                                               30.  Rathod DA, Kaur A, Patel V, et al: Usefulness of cell counter-based parameters and
                                                                         formulas in detection of beta-thalassemia trait in areas of high prevalence. Am J Clin
                  1.  Barnes PW, McFadden SL, Machin SJ, Simson E: The international consensus group   Pathol 128:585–589, 2007.
                   for hematology review: Suggested criteria for action following automated CBC and     31.  Lafferty JD, Crowther MA, Ali MA, Levine M: The evaluation of various mathemat-
                   WBC differential analysis. Lab Hematol 11:83–90, 2005.  ical RBC indices and their efficacy in discriminating between thalassemic and non-
                  2.  Sireci A, Schlaberg R, Kratz A: A method for optimizing and validating institution-   thalassemic microcytosis. Am J Clin Pathol 106:201–205, 1996.
                   specific flagging criteria for automated cell counters.  Arch  Pathol Lab  Med 134:     32.  Jolobe OM: Mean corpuscular haemoglobin, referenced and resurrected. J Clin Pathol
                   1528–1533, 2010.                                      64:833–834, 2011.
                  3.  Gulati G, Song J, Florea AD, Gong J: Purpose and criteria for blood smear scan, blood     33.  Brugnara C, Mohandas N: Red cell indices in classification and treatment of anemias:
                   smear examination, and blood smear review. Ann Lab Med 33:1–7, 2013.  From M.M. Wintrobes’s original 1934 classification to the third millennium.  Curr
                  4.  Kim SJ, Kim Y, Shin S, et al: Comparison study of the rates of manual peripheral blood   Opin Hematol 20:222–230, 2013.
                   smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA     34.  Patel A, Brett SJ: Identifying future risk from routine tests?  Crit Care Med 42:
                   2120i, and XE 2100, using international consensus group guidelines. Arch Pathol Lab   999–1000, 2014.
                   Med 136:1408–1413, 2012.                             35.  Gul M, Uyarel H, Ergelen M, et al: The relationship between red blood cell distribution
                  5.  Hur M, Cho JH, Kim H, et al: Optimization of laboratory workflow in clinical hema-  width and the clinical outcomes in non-ST elevation myocardial infarction and unsta-
                   tology laboratory with reduced manual slide review: Comparison between Sysmex   ble angina pectoris: A 3-year follow-up. Coron Artery Dis 23:330–336, 2012.
                   XE-2100 and ABX Pentra DX120. Int J Lab Hematol 33:434–440, 2011.    36.  Patel KV, Semba RD, Ferrucci L, et al: Red cell distribution width and mortality in
                  6.  Hotton J, Broothaers J, Swaelens C, Cantinieaux B: Performance and abnormal cell   older adults: A meta-analysis. J Gerontol A Biol Sci Med Sci 65:258–265, 2010.
                   flagging comparisons of three automated blood cell counters: Cell-Dyn Sapphire,     37.  Hunziker S, Stevens J, Howell MD: Red cell distribution width and mortality in newly
                   DxH-800, and XN-2000. Am J Clin Pathol 140:845–852, 2013.  hospitalized patients. Am J Med 125:283–291, 2012.
                  7.  Ceelie H, Dinkelaar RB, van Gelder W: Examination of peripheral blood films using     38.  Zorlu A, Bektasoglu G, Guven FM, et al: Usefulness of admission red cell distribution
                   automated microscopy; evaluation of Diffmaster Octavia and Cellavision DM96.  J   width as a predictor of early mortality in patients with acute pulmonary embolism. Am
                   Clin Pathol 60:72–79, 2007.                           J Cardiol 109:128–134, 2012.
                  8.  Smits SM, Leyte A: Clinical performance evaluation of the CellaVision Image Capture     39.  Lam AP, Gundabolu K, Sridharan A, et al: Multiplicative interaction between mean
                   System in the white blood cell differential on peripheral blood smears. J Clin Pathol   corpuscular volume and red cell distribution width in predicting mortality of elderly
                   67:168–172, 2014.                                     patients with and without anemia. Am J Hematol 88:E245–E249, 2013.
                  9.  Buttarello M, Plebani M: Automated blood cell counts: state of the art. Am J Clin     40.  Wang F, Pan W, Pan S, et al: Red cell distribution width as a novel predictor of mortal-
                   Pathol 130:104–116, 2008.                             ity in ICU patients. Ann Med 43:40–46, 2011.
                  10.  Coulter WH: High speed automatic blood cell counter and cell size analyzer. Proc Natl     41.  Lippi G, Targher G, Montagnana M, et al: Relation between red blood cell distribution
                   Elect Conf 12:1034, 1956.                             width and inflammatory biomarkers in a large cohort of unselected outpatients. Arch
                  11.  Meintker L, Ringwald J, Rauh M, Krause SW: Comparison of automated differen-  Pathol Lab Med 133:628–632, 2009.
                   tial blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter     42.  Piva E, Brugnara C, Chiandetti L, Plebani M: Automated reticulocyte counting: State
                   DxH 800, and Sysmex XE-2100 in normal and pathologic samples. Am J Clin Pathol   of the art and clinical applications in the evaluation of erythropoiesis. Clin Chem Lab
                   139:641–650, 2013.                                    Med 48:1369–1380, 2010.
                  12.  Lippi G, Cattabiani C, Benegiamo A, et al: Evaluation of the fully automated hemato-    43.  Noronha JF, De Souza CA, Vigorito AC, et al: Immature reticulocytes as an early pre-
                   logical analyzer Sysmex XE-5000 for flow cytometric analysis of peritoneal fluid. J Lab   dictor of engraftment in autologous and allogeneic bone marrow transplantation. Clin
                   Autom 18:240–244, 2013.                               Lab Haematol 25:47–54, 2003.
                  13.  Perne A, Hainfellner JA, Womastek I, et al: Performance evaluation of the Sysmex     44.  Buttarello M, Bulian P, Farina G, et al: Five fully automated methods for performing
                   XE-5000 hematology analyzer for white blood cell analysis in cerebrospinal fluid. Arch   immature reticulocyte fraction: Comparison in diagnosis of bone marrow aplasia. Am
                   Pathol Lab Med 136:194–198, 2012.                     J Clin Pathol 117:871–879, 2002.
                  14.  Paris A, Nhan T, Cornet E, et al: Performance evaluation of the body fluid mode on the     45.  Urrechaga E, Borque L, Escanero JF: The role of automated measurement of RBC
                   platform Sysmex XE-5000 series automated hematology analyzer. Int J Lab Hematol   subpopulations in differential diagnosis of microcytic anemia and beta-thalassemia
                   32:539–547, 2010.                                     screening. Am J Clin Pathol 135:374–379, 2011.
                  15.  Briggs C, Kimber S, Green L: Where are we at with point-of-care testing in haematol-    46.  Schoorl M, Schoorl M, Linssen J, et al: Efficacy of advanced discriminating algorithms
                   ogy? Br J Haematol 158:679–690, 2012.                 for  screening  on  iron-deficiency  anemia  and  beta-thalassemia  trait:  A  multicenter
                  16.  England JM, Walford DM, Waters DA: Re-assessment of the reliability of the haemat-  evaluation. Am J Clin Pathol 138:300–304, 2012.
                   ocrit. Br J Haematol 23:247–256, 1972.               47.  Higgins JM, Mahadevan L: Physiological and pathological population dynamics of
                  17.  Fairbanks VF: Nonequivalence of automated and manual hematocrit and erythrocyte   circulating human red blood cells. Proc Natl Acad Sci U S A 107:20587–20592, 2010.
                   indices. Am J Clin Pathol 73:55, 1980.               48.  Weatherall DJ: Systems biology and red cells. N Engl J Med 364:376–377, 2011.
                  18.  England JM: Blood Cell Sizing. Churchill Livingstone, New York, 1991.    49.  Thomas L, Franck S, Messinger M, et al: Reticulocyte hemoglobin measurement—
                  19.  Shamir MY, Avramovich A, Smaka T: The current status of continuous noninvasive   comparison of two methods in the diagnosis of iron-restricted erythropoiesis. Clin
                   measurement of total, carboxy, and methemoglobin concentration.  Anesth Analg   Chem Lab Med 43:1193–1202, 2005.
                   114:972–978, 2012.                                   50.  KDOQI; National Kidney Foundation: KDOQI clinical practice guidelines and clini-
                  20.  Lindner G, Exadaktylos AK: How noninvasive haemoglobin measurement with pulse   cal practice recommendations for anemia in chronic kidney disease. Am J Kidney Dis
                   co-oximetry can change your practice: An expert review. Emerg Med Int 2013:701529,   47(5 Suppl 3):S11–S145, 2006.
                   2013.                                                51.  Mast AE, Blinder MA, Lu Q, et al: Clinical utility of the reticulocyte hemoglobin con-
                  21.  Dewhirst E, Naguib A, Winch P, et al: Accuracy of noninvasive and continuous hemo-  tent in the diagnosis of iron deficiency. Blood 99:1489–1491, 2002.
                   globin measurement by pulse co-oximetry during preoperative phlebotomy. J Inten-    52.  Ullrich C, Wu A, Armsby C, et al: Screening healthy infants for iron deficiency using
                   sive Care Med 29:238–242, 2013.                       reticulocyte hemoglobin content. JAMA 294:924–930, 2005.
                  22.  Rice MJ, Gravenstein N, Morey TE: Noninvasive hemoglobin monitoring: How accu-    53.  Urrechaga E, Borque L, Escanero JF: Erythrocyte and reticulocyte indices in the
                   rate is enough? Anesth Analg 117:902–907, 2013.       assessment of erythropoiesis activity and iron availability.  Int J Lab Hematol 35:
                  23.  Dallman PR, Siimes MA: Percentile curves for hemoglobin and red cell volume in   144–149, 2013.
                   infancy and childhood. J Pediatr 94:26, 1979.        54.  Buttarello M, Pajola R, Novello E, et al: Diagnosis of iron deficiency in patients under-
                  24.  Wintrobe MM: Anemia: Classification and treatment on the basis of differences in   going hemodialysis. Am J Clin Pathol 133:949–954, 2010.
                   the average volume and hemoglobin content of the red corpuscles. Arch Intern Med     55.  Joosten E, Lioen P, Brusselmans C, et al: Is analysis of the reticulocyte haemoglo-
                   54:256, 1934.                                         bin equivalent a useful test for the diagnosis of iron deficiency anaemia in geriatric
                  25.  Seward SJ, Safran C, Marton KI, Robinson SH: Does the mean corpuscular volume   patients? Eur J Intern Med 24:63–66, 2013.
                   help physicians evaluate hospitalized patients with anemia?  J Gen Intern Med 5:     56.  Osta V, Caldirola MS, Fernandez M, et al: Utility of new mature erythrocyte and retic-
                   187–191, 1990.                                        ulocyte indices in screening for iron-deficiency anemia in a pediatric population. Int J
                  26.  Carmel R: Pernicious anemia. The expected findings of very low serum cobalamin   Lab Hematol 35:400–405, 2013.
                   levels, anemia, and macrocytosis are often lacking. Arch Intern Med 148:1712–1714,     57.  Yoo JH, Song J, Lee KA, et al: Automated detection of malaria-associated pseudoeo-
                   1988.                                                 sinophilia and abnormal WBC scattergram by the Sysmex XE-2100 hematology ana-
                  27.  Sekhar J, Stabler SP: Life-threatening megaloblastic pancytopenia with normal mean   lyzer: A clinical study with 1,801 patients and real-time quantitative PCR analysis in
                   cell volume: Case series. Eur J Intern Med 18:548–550, 2007.  vivax malaria-endemic area. Am J Trop Med Hyg 82:412–414, 2010.
                  28.  Mahmoud MY, Lugon M, Anderson CC: Unexplained macrocytosis in elderly     58.  Lee HK, Kim SI, Chae H, et al: Sensitive detection and accurate monitoring of Plas-
                   patients. Age Ageing 25:310–312, 1996.                modium vivax parasites on routine complete blood count using automatic blood cell
                  29.  Eldibany MM, Totonchi KF, Joseph NJ, Rhone D: Usefulness of certain red blood cell   analyzer (DxH800(TM)). Int J Lab Hematol 34:201–207, 2012.
                   indices in diagnosing and differentiating thalassemia trait from iron-deficiency ane-    59.  Amundsen EK, Urdal P, Hagve TA, et al: Absolute neutrophil counts from automated
                   mia. Am J Clin Pathol 111:676–682, 1999.              hematology instruments are accurate and precise even at very low levels. Am J Clin
                                                                         Pathol 137:862–869, 2012.






          Kaushansky_chapter 02_p0011-0026.indd   24                                                                    17/09/15   5:35 pm
   43   44   45   46   47   48   49   50   51   52   53