204                       Applied Process Design for Chemical  and Petrochemical  Plants







                            �I   80




                         u,
                         a:      60
                         0   >
                         ....  (J
                         (J   z   100
                         �  LI.I
                         u.   u
                         z   i:i:
                         0  u.
                         j:::  w   80
                         (J   Q
                         a:  z
                         LI.I
                         a:  �
                         0
                         (J   �   60
                            u
                            �
                            A.
                            �
                            (J   40














                            -

                            LI.I
                            0
                            �
                            ....
                            u,
                            ....
                            u,
                            a:
                            i:i:
                            tu   600
                                 400
                            LI.I   300
                            u.   2og
                            -    100
                                 15
                            z
                                  80
                            Q    60
                            �     40
                            LI.I
                            ::c   lg
                                    1        2         4    6    8  10   15   20       40    60   80 100
                                                       CAPACITY  IN  100  GPM
             Figure 3-56. Viscosity performance correction chart for centrifugal  pumps.  Note:  do not extrapolate.  For  centrifugal  pumps only,  not for axial
             or mixed flow.  NPSH must be adequate.  For Newtonian fluids only.  For multistage pumps, use head per stage.  (By permission, Hydraulic  Insti-
             tute Standards for Centrifugal,  Rotary.  and Reciprocating Pumps,  13th ed., Hydraulic Institute,  1975.)