Page 236 - ACCCN's Critical Care Nursing
P. 236
Cardiovascular Assessment and Monitoring 213
Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: 45. Truwit JD. Technique and measurements: getting a line on the hemodynamic
Endorsed by the International Society of Computerized Electrocardiology undercurrent. J Crit Illness 2003; 18(1): 9–20.
and the American Association of Critical-Care Nurses. Circulation 2004; 46. Ruesch S, Walder B, Tramèr MR. Complications of central venous catheters:
110(17): 2721–6. internal jugular versus subclavian access – a systematic review. Crit Care Med
15. Jacobson C. Bedside cardiac monitoring. Critical Care Nurse 2003; 23(6): 2003; 30(2): 454–60.
71–3. 47. Rubinson L, Diette GB. Best practices for insertion of central venous catheters
16. Shoemaker WC. Routine clinical monitoring in acute illness. In: Shoemaker in intensive care units to prevent catheter-related bloodstream infections.
WC, Vehmohos GC, Demetridas D, eds. Procedure and monitoring for the criti- J Lab Clin Med 2004; 143(1): 5–13.
cally ill. Philadelphia: W.B. Saunders; 2002. p. 155–66. 48. Swanz HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Cath-
17. Urden L, Stacy KL, Lough ME, eds. Critical care nursing: diagnosis and manage- eterisation of the heart in man with use of flow-directed balloon-tipped
ment, 6th edn. St Louis: Mosby/Elsevier; 2010. catheter. N Eng J Med 1970; 283(9): 447–51.
18. Conover MB. Understanding electrocardiography, 8th edn. St Louis: Mosby; 49. Truwit JD. The pulmonary artery catheter in the ICU, part 2: clinical applica-
2003. tions; how to interpret the hemodynamic picture. J Crit Illness 2003; 18(2):
19. Morris F, Brady WJ. Clinical review: ABC of clinical electrocardiography. 63–71.
Acute myocardial infarction – Part I. BMJ 2002; 324: 831–4. 50. Dalen JE, Bone RC. Is it time to pull the pulmonary artery catheter? JAMA
20. Americal Heart Association. Myocardial ischemia, injury and infarction. 1996; 276(11): 916–18.
2008. Available from: http://www.americanheart.org/presenter.jhtml? 51. Prentice D, Ahrens T. Controversies in the use of the pulmonary artery
identifier=251. catheter. J Cardiovas Nurs 2001; 15(2): 1–5.
21. Raistin AM, Soars L. Nursing assessment: cardiovascular system. In: Brown 52. Society of Critical Care Medicine. Pulmonary Artery Catheter Consenus
D, Edwards H, eds. Lewis’ medical-surgical nursing. Sydney: Mosby/Elsevier; conference. Consensus statement. Crit Care Med 1997; 25(6):
2005. 910–25.
22. Aitken LM. Critical care nurses’ use of decision-making strategies. J Clin Nurs 53. Chittock DR, Dhingra VK, Ronco JJ, Russell JA, Forrest DM et al. Severity of
2003; 12(4): 476–83. illness and risk of death associated with pulmonary artery catheter use. Crit
23. Chaney JC, Derdak S. Minimally invasive haemodynamic monitoring for the Care Med 2004; 32(4): 911–15.
intensivist: current and emerging technology. Crit Care Med 2002; 30(10): 54. Harvey S, Harrison D, Singer M, Ashcroft J, Jones CM et al. Assessment of
2338–45. the clinical effectiveness of pulmonary artery catheters in management of
24. Pinsky MR. Rationale for cardiovascular monitoring. Curr Opin Crit Care patients in intensive care (PAC-Man): a randomized controlled trial. Lancet
2003; 9(3): 222–4. 2005; 366: 472–7.
25. Dietz B, Smith TT. Enhancing the accuracy of haemodynamic monitoring. 55. Harvey S, Young D, Brampton W, Cooper A, Doig GS et al. Pulmonary artery
J Nurs Care Qual 2002; 17(1): 27–34. catheters for adult patients in intensive care. Cochrane Database of Systematic
26. Rice WP, Fernandez EG, Jarog D, Jensen A. A comparison of hydrostatic level- Reviews 2006; (3).
ing methods in invasive pressure monitoring. Crit Care Nurse 2000; 20(6): 56. Cruz K, Franklin C. The pulmonary artery catheter: uses and controversies.
20–30. Crit Care Clinics 2001; 17(2): 271–91.
27. McGhee BH, Bridges MEJ. Monitoring aterial blood pressure: what you may 57. Bridges EJ. Pulmonary artery pressure monitoring: when, how, and what else
not know. Crit Care Nurse 2002; 22(2): 60–79. to use. AACN Adv Crit Care 2006;17(3): 286–303.
28. American Association of Critical Care Nurses (AACN). Pulmonary artery 58. Woodrow P. Intensive care nursing. London: Routledge; 2000.
pressure monitoring. 2004 [Cited July 2010]. Available from: www.aacn.org. 59. Bowdle TA. Complications of invasive monitoring. Anaesthesiology Clinics N
29. Quaal SJ. Improving the accuracy of pulmonary artery catheter measure- Am 2002; 20(3): 571–8.
ments. J Cardiovas Nurs 2001; 15(2): 71–82. 60. Ritzema J, Troughton R, Melton I, Crozier I, Doughty R et al. Physician-
30. Australian Council of Health Care Standards. Intensive Care Indicators directed patient self-management of left atrial pressure in advanced chronic
Version 3. 2006. [Cited Jan 2011]. Available at: http://www.achs.org.au/ heart failure. Circulation 2010; 121(9): 1086–95.
31. Intensive Care Clinical Advisory Group. Intensive care services in New Zealand: 61. Ott K, Johnson K, Ahrens T. New technologies in the assessment of hemo-
a report to the Deputy Director-General, Clinical Services. Wellington: Ministry dynamic parameters. J Cardiovascular Nurs 2001; 15(2): 41–55.
of Health; 2005. 62. Carelock J, Clark AP. Heart failure: pathophysiologic mechanisms. Am J Nurs
32. O’Sullivan J, Allen J, Murray A. The forgotten Korotkoff phases: how often 2001; 101(12): 26–33.
are phases II and III present and how often do they relate to the other 63. Rodgers JM, Reeder SJ. Current therapies in the management of systolic and
Korotkoff phases? Am J Hypertension 2002; 15(3): 264–8. diastolic dysfunction. Dimensions Crit Care Nurs 2001; 20(6): 2–10.
33. Dobbin KR. Non-invasive blood pressure monitoring. Crit Care Nurse 2002; 64. Lough ME. Cardiovascular assessment and diagnostic procedures. In: Urden
22(2): 123–4. L, Stacy KL, Lough ME, eds. Priorities in critical care nursing. St Louis: Mosby;
34. Hung DT, Lilly CM. Making the most of hemodynamic monitoring in the 2004.
ICU: observing and optimizing appropriate parameters. J Crit Illness 2003; 65. Gödje O, Höke K, Goetz AE, Felbinger TW, Reuter DA et al. Reliability of a
18(5): 198–208. new algorithm for continuous cardiac output determination by pulsecon-
35. Imperial-Perez F, McRae M. Arterial pressure monitoring. Crit Care Nurse tour analysis during hemodynamic instability. Crit Care Med 2002; 30(1):
2002; 22(1): 70–72. 52–8.
36. Chatfield D, Rees-Padlar S. Jugular venous oxygen saturation: is it relevant 66. Moser DK, Reigel B. Cardiac nursing: a companion to Brauwald’s heart disease.
to the nurse? Nurs Crit Care 2001; 6(4):187–91. St Louis: Elsevier; 2008.
37. Woodrow P. Central venous catheters and central venous pressure. Nurs 67. Faybik P, Hetz H, Baker A, Yankovskaya E, Krenn CG, Steltzer H. Iced versus
Stand 2002; 16(26): 45–51. room temperature injectate for assessment of cardiac output, intrathoracic
38. Bellomo R, Uchino S. Cardiovascular monitoring tools: use and misuse. Curr blood volume and extravascular lung water by single transpulmonary ther-
Opin Crit Care 2003; 9(3): 225–9. modilution. J Crit Care 2004; 19(2): 103–7.
39. Kumar A, Anel R, Bunnell E, Habet K, Zanotti S et al. Pulmonary artery 68. Cottis R, Magee N, Higgins DJ. Haemodynamic monitoring with pulse-
occlusion pressure and central venous pressure fail to predict ventricular induced contour cardiac output (PiCCO) in critical care. Intens Crit Care Nurs
filling volume, cardiac performance, or the response to volume infusion in 2003; 19(5): 301–7.
normal subjects. Crit Care Med 2004; 32(3): 691–9. 69. Salukhe TV, Wyncoll DL. Volumetric haemodynamic monitoring and con-
40. Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end- tinuous pulse contour analysis: an untapped resource for coronary and high
diastolic volume as an indicator of cardiac preload in patients with septic dependency care units? Brit J Cardiology (Acute and Interventional Cardiology)
shock. Chest 2003; 124(5): 1900–8. 2002; 9(1): 20–25.
41. Weyland A, Grune F. Cardiac preload and central venous pressure. Anaesthe- 70. Gödje O, Friedl R, Hannekum A. Accuracy of beat-to-beat cardiac output
tist 2009; 58(5): 506–12. monitoring by pulse contour analysis in hemodynamical unstable patients.
42. Pinsky MR. Functional hemodynamic monitoring. Intens Care Med 2002; Med Sci Monitor 2001; 7(6): 1344–50.
28(4): 392–8. 71. Hofer CK, Bulmann S, Jaeggi P, Genoni M, Zollinger A. Cardiac output
43. Schummer W. Central venous pressure. Validity, informative value and measurement after cardiac surgery: Thermodilution compared with two
correct measurement. Anaesthetist 2009; 58(5): 499–505. alternative methods. Euro J Anaesthesiol 2002; 19(Suppl. 27): 9–11.
44. McGee DC, Gould MK. Current concepts: preventing complications 72. Chung F-T, Lin S-M, Lin S-Y, Lin H-C. Impact of extravascular lung water
of central venous catheterization. N Eng J Med 2003; 348(12): index on outcomes of severe sepsis patients in a medical intensive care unit.
1123–33. Resp Med 2008; 102(7): 956–61.

