Page 237 - ACCCN's Critical Care Nursing
P. 237
214 P R I N C I P L E S A N D P R A C T I C E O F C R I T I C A L C A R E
73. Jansen JJ. The thermodilution method for the clinical assessment of cardiac with conventional echocardiography and cardiac catheterization. Portuguese
output. Intens Care Med 1995; 21(8): 691–7. J Cardiology 2002; 21(5): 555–72.
74. Martin GS, Eaton S, Mealer M, Moss M. Extravascular lung water in patients 90. Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A et al.
with severe sepsis: a prospective cohort study. Crit Care 2005;9(2):74–82. Echocardiographic assessment of valve stenosis: EAE/ASE Recommendations
75. King S, Lim T. The use of the oesophageal Doppler monitor in the intensive for clinical practice. Morrisville, NC: American Society of Echocardio graphy;
care unit. Crit Care Resusc 2004; 6(2): 113–22. 2010.
76. Hett A, Jonas MM. Non-invasive cardiac output monitoring. Intens Crit Care 91. Royal College of Pathoiogists Australasia. RCPA manual. Version 46. 2011.
Nurs 2004; 20(2): 103–8. [Cited March 2011]. Available at: http://www.rcpa.edu.au/Publications/
77. Turner MA. Doppler-based haemodynamic monitoring. AACN Clinical Issues RCPAManual.htm.
2003; 14(2): 220–31. 92. Pagana KD. Mosby’s diagnostic and laboratory test reference, 8th edn. St Louis:
78. Bein B, Renner J, Tonner PH. Transoesophageal echocardiography for the Mosby/Elsevier; 2007.
determination of cardiac output: beware of improper comparisons. Anaes- 93. Van Bockel EAP, Tulleken JE, Ligtenberg JJM, Zijlstra JG. Troponin in septic
thesia 2005; 60(5): 512–14. and critically ill patients. Chest 2005; 127(2): 687–8.
79. Engoren M, Barbee D. Comparison of cardiac output determined by bio- 94. Ammann P, Maggiorini M, Bertel O, Haenseler E, Joller-Jemelka HI et al.
impedance, thermodilution and the Fick method. Am J Crit Care 2005; Troponin as a risk factor for mortality in critically ill patients without acute
14(1): 40–45. coronary syndromes. J Am College Cardiol 2003; 41(11): 2004–9.
80. Bettex DA, Hinselmann V, Hellermann JP, Jenni R, Schmid ER. Transo- 95. Klein-Gunnewiek JMK, Van der hoeven JG. Cardiac troponin elevations
esophageal echocardiography is unreliable for cardiac output assessment among critically ill patients. Curr Opin Crit Care 2004; 10: 324–46.
after cardiac surgery compared with thermodilution. Anaesthesia 2004; 96. Erkonen WE, Wilbur LS. Radiology 101: the basics and fundamentals of imaging,
59(12): 1184–92. 3rd edn. Philadelphia, PA: Lippincott Williams & Wilkins; 2009.
81. McLean AS. Transoesophageal echocardiography in the intensive care unit. 97. Lareau C, Wootton J. The ‘frequently’ normal chest x-ray. Canadian J Rural
Anaesthesia Intens Care 1998; 26(1): 22–5. Med 2004; 9(3): 183–6.
82. Atlas G, Mort T. Placement of the esophageal Doppler ultrasound probe in 98. Malcolm J, Arnold O. Heart Failure. The MERCK manual for healthcare profes-
awake patients. Chest 2001; 119(1): 319. sionals. 2009. Available from: http://www.merckmanuals.com/professional/
83. Miyagawa S, Masai T, Fukuda H, Yamauchi T, Iwakura K, Itoh H et al. Coro- sec07/ch074/ch074a.html
nary microcirculatory dysfunction in aortic stenosis: myocardial contrast 99. McGoon M, Gutterman D, Steen V, Barst R, McCrory DC et al. Screening,
echocardiography study. Annals Thoracic Surg 2009; 87: 715–19. early detection, and diagnosis of pulmonary arterial hypertension: ACCP
84. Haas LEM, Tjan DHT, van Wees J, van Zanten ARH, eds. Validation of evidence-based clinical practice guidelines. Chest 2004; 126(1 Suppl):
the USCOM-1A cardiac output monitor in hemodynamic unstable intensive S14–34.
care patients. Conference Paper: Annual Intensive Care Society Congress, 100. Parmet S, Lynm C, Glass RM. Pericarditis. JAMA 2003; 289(9): 1194.
Netherlands; 2006. 101. O’Brien T, Paul S. Chest x-ray and vascular studies. In: Taylor G, ed. Primary
85. Lasater M, VonRueden KT. Outpatient cardiovascular management care management of heart disease. St Louis: Mosby; 2000.
utilizing impedance cardiography. AACN Clinical Issues 2003; 14(2): 102. Wijesekera NT, Duncan MK, Padley SPG. X-ray computed tomography of the
240–50. heart. Brit Med Bull 2010; 93: 49–67.
86. Albert NM. Bioimpedance cardiography measurements of cardiac output 103. Ropers D. Multislice computer tomography for detection of coronary artery
and other cardiovascular parameters. Crit Care Nursing Clinics N Am 2006; disease. J Interventional Cardiol 2006; 19: 574–82.
18(2): 195–202. 104. Lima J, Desai M. Cardiovascular magnetic resonance imaging: current and
87. Sageman WS, Riffenburgh RH, Spiess BD. Equivalence of bioimpedance and emerging applications. J Am College Cardiol 2004; 44: 1164–71.
thermodilution in measuring cardiac index after cardiac surgery. J Cardiotho- 105. Paetsch I, Gebker R, Fleck E, Nagel E. Cardiac magnetic resonance imaging:
racic Vascular Anesthesia 2002; 16(1): 8–14. a noninvasive tool for functional and morphological assessment of coronary
88. Raaijmakers E, Faes TJ, Scholten RJ, Goovaerts HG, Heethaar RM. A meta- artery diease: current clinical applications and potential future concepts. J
analysis of three decades of validating thoracic impedance cardiography. Crit Interventional Cardiol 2003; 16: 457–63.
Care Med 1999; 27(6): 1203–13. 106. Lewis J. Fluid and electrolytes metabolism The MERCK manual for healthcare
89. Almeida AG, Sargento L, Gabriel HM, da Costa JM, Morais J et al. Evaluation professionals. 2009: Available from: http://www.merck.com/mmpe/sec12/
of aortic stenosis severity: role of contrast echocardiography in comparison ch156/ch156b.html.