             12.  Maintenance
             12-1  Caution points when handle the EV: Electric Vehicle
             i-MiEV uses DC 330V and has a possibility to courses the serious accident as electrical shock to the human body
             if it is handled wrongly.
             Therefore, Technical staff who inspect / maintenance the i-MiEV as Electrical vehicle should be completed
             the special training course for the electric power handling.


             [Handling of the insulation grooves]
             Entrepreneur should inspect the all of insulation goods  for AC300V or more every 6 months and should confirm
             the insulation performance on a voluntary basis.
             Insulation goods which have not used for 6 months will be excluded from the inspection.
             However, Entrepreneur should inspect insulation goods before use.
             If the Entrepreneur found the abnormality in these insulation goods, Entrepreneur is required to repair or replace.
             Entrepreneur should inspect for the following items and record every inspection history and store the records for
             3 years.

             -Inspection date
             -Inspection method
             -Inspection part
             -Inspection result
             -Inspector’s name
             -Measure (if problem is found)