Page 37 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 37

22                       Applied  Process  Design  for Chemical  and  Petrochemical  Plants



                    Gate Valve                                                                             Removable  Pipe
                                                                                Fiiter-Air Intake          Spool
                    Globe  Valve
                                     Angle  Valve   Fire  Hydrant                              :::c    --.-   Steam  Traced
                                                                                Air Cleaner                Line
                                   --i-               iP.T.                     (Compressor
                    Plug  Cock                                                  Suction)
                                        l{s.c.    _J_                                           c�-T       Steam  Jacketed
                                                                                                           Line
                    Plug  Valve                                                  Steam
           -        Check  Valve   Sample Connection   Pressure  Tap            Separator     t  --  t     Duct

                                           --M--
           -        Stop  Check      c.s.o.  =  Car Sealed  Open   --v                                     Swage
                                     C.S.C.  =  Car Sealed  Closed

                    Slowdown  Valve    LO.  =  Locked  Open                     BooUog         --D-        Dresser
                                       LC.  =  Locked  Closed
                                        -a-                       1J
                                                                                                           Coupling
                    Ball  Valve                     Filter               1Jj    Seal  Leo,           y
                                                                                                           Equipment
                    Butterfly Valve                                                                        Drain  Funnel
                                                    Strainer                  YGage                        Area  Drain
                                                    (B  =  Basket,   --.:r:(__                             Fitting
                    Manually Operated               C  =  Cone,                      Hatch
                    Control  Valve                   P  =  Plate)
                                                                                                           Drain  Conn.  to
                                                                            P  Maahole                     Closed  System
                     Diaphragm  Valve               "T"  Type Strainer
                                                                             @
                     Needle Valve         I   '-;  I   "Y" Type  Strainer        Flame Arrester
                     (Tag  on  Flow  Sheet)
            N.V.                                                                                           Steam
                                                                             '                             Exhaust Head
                     Three-Way  Plug                                             Diffuser
                     Valve                          Twin  Basket                                           Sample
                                                    Fiiier                                                 Cooler
                                                                     � Mixer
                     Four-Way  Plug
                     Valve                                           -----J  Screwed  Cap
                                                    Trap-Steam                                  ---;'?...,_._  Slip  Blind
                     Three-Way
                     Valve                                           -----D  Weld  Cap
                                                    Trap-Vacuum                                            Spectacle
                                                    Booster (Lift)                                         Blind
                     Slide Valve                                     -----11  Blind  Flange

                     Angle  Valve       --$  Spray  Nozzle
                                                                           If�   Bull  Plug                Hamer Blind
                     Stop  Check  Angle
                     Valve                          Suction  Tee            If                              Expansion
                                                                               SJ  Pipe  Plug
                                                                                                            Joint
                     Boller  Slowdown               Ejector,  Eductor,                                      Open  Drain
                     Valve  (Tandem)                                 -----IC  Hose Connection               to  Sewer
           �                                        Injector
                                                    &  Exhauster
                                                                                 Flexible  Hose
        t  l'•,lt:=1,  Damper                                                                      I   I  _.  Strainer
                                                                                 with  Connection   \,

           Figure 1-20C.  Flow diagram symbols:  valves,  fittings and miscellaneous piping.  (Compiled from several  sources,  and in  particular,  Fluor
           Corp,  Ltd.)
   32   33   34   35   36   37   38   39   40   41   42