                 Rb82  is  a monovalent  cation  and has ultra short   base at  the  rim. Both relative and  absolute flow re-
                 half life  75 sec. Sr-82  decays to an elution column.   serve can be depicted on quantitative polar maps on
                 Rb82 is eluted with 25 to 50 ml of normal saline by   Rb82 activity. In this manner the rest and stress imag-
                 a computer controlled elution pump, connected  by   es are functionally interrelated. Three dimensional (3-
                 IV  tubing to the patient. This  generator  has almost   D) topographic  displays  of  Rb82  cardiac activity are
                 no breakthrough of strontium and has useful life of   more quantitative with respect to the polar maps. An
                 4-6  weeks.  Serial  evaluations  of regional  myocardi-  automated  quantitative  analysis  programmed  may
                 al perfusion can  be made  at  intervals as short as 5   enhance accuracy and reproducibility of cardiac PET
                 minutes. The short half life of Rb82 taxes the perfor-  flow studies.
                 mance limits of PET scanners; it facilitates the rapid    The sensitivity and specificity of PET MPI are superi-
                 completion of a series of resting and stress myocar-  or to other non-invasive tests. Four studies involving
                 dial perfusion studies. Rb-82 is a very efficient imag-  a total of 342 patients have made direct comparisons
                 ing agent for routine clinical usage. Although the cost   of Tl-201 SPECT and PET MPI. In addition a survey of
                 per patient at a low volume of studies per day is high,   numerous studies of PET MPI in 1391 patients found
                 the cost with 6 to 10 studies  per  day  is  competitive   excellent sensitivity (92%: C I = 90% to 94%) and spec-
                 with SPECT tracers.
                                                                    ificity (90% C I = 88% to 92%). Church well et al has
                  The first pass extraction of Rb-82 at rest is approx-  also shown greater accuracy in a blinded analysis of
                 imately 50-60%  and it’s via Na+/K+  AT  pase  pump.   the accuracy of 82 Rb PET in 194 patients with new
                 Myocardial extraction of Rb-82 is similar to thallium   quantitative  software developed  in their laboratory.
                 – 201 and slightly less than N-13 ammonia, decreasing   Patterson et al has also shown  significantly better
                 during hyperemia  .Rb- 82  extraction  can  be altered   results with 82-Rb PET than their own SPECT Tl-201
                 by  severe  acidotic hypoxia  and ischemia. (36).  Thus   results.  These comparisons  and Emory University’s
                 uptake of Rb-82. is a function of both blood flow and   extensive  clinical experiences  (over 30,000  SPECT
                 of myocardial cell integrity. Rb-82 perfusion imaging   Tl-201 and over  2000  MPI.  Though all patients with
                 is  usually  performed  before  and after vasodilator   intermediate risk of coronary artery disease can un-
                 stress  rather than  with  exercise.  Infracted  myocar-  dergo  PET MPI, it is  preferable  to SPECT  MPI  in a
                 dium doesn’t retain  intravenously  administered  Rb-  subgroup  of patients with  attenuation  problems  i.e
                 82.  After administration,  it washes out  rapidly  from   large  patients, women,  breast implants or  left mas-
                 damaged myocardial cells following the initial uptake   tectomy, chest wall deformity, left pleural or pericar-
                 phase. A mixture of reversible and irreversible myo-  dial effusion. However  it must be emphasized that
                 cardial tissue in the field of view results in an inter-  attenuation problems in SPECT can not be predicted
                 mediate level of Rb-82 wash out that is proportional   with  confidence from examination  of body habitus.
                 to the percentage of viable or infracted tissue.   There  is  an incremental benefit caused by  greater
                                                                    specificity  and  sensitivity  which gives  rise  to incre-
                 Imaging of Rb-82:                                  mental economic benefit caused by  more  accurate
                                                                    tests like Rb82 PET MPI.
                 Patient preparation  for  stress  and rest  myocardial
                 PET  perfusion  imaging  is  identical to SPECT  perfu-  During the last 10 to 15 years ,both SPECT and PET im-
                 sion imaging.  Despite  the short half-life  of Rb82,   aging have undergone significant improvements . A
                 modern PET gamma cameras are able to obtain good   recent comparison between Tc-99m sestamibi SPECT
                 quality  images.  The  usual protocol  takes  approxi-  and Rb82  PET MPI  revealed  a significant margin of
                 mately 15  minutes with a BGO crystal  PET  scanner   improvement for CAD detection accuracy with Rb82
                 and 35 minutes with LSO crystals PET scanner. The   PET compared to SPECT (38). Given the proven value
                 proper  positioning  is  done with a low dose  (20mci)   of PET myocardial perfusion imaging in the diagnosis
                 injection of Rb-82 and short 3 minutes scout acqui-  of CAD,  it is expected  that  the prognostic  value of
                 sition and  quick reconstruction.  Subsequently, rest   gated PET is also high, similar to SPECT imaging.
                 transmission imaging, rest perfusion 2D imaging and    T in cardiac imaging is reduction in acquisition time
                 rest gated 3D imaging were done sequentially. Stress   by  10-12 minutes in comparison  to a dedicated PET
                 imaging is also done in similar manner. Transmission   system. PET-CT imaging holds challenges and solu-
                 imaging is usually done with a germanium-68 pin or
                 rod source, which takes about 8 minutes.           tion for the attenuation correction problem.
                  Tomographic data  from Rb82  images  can  be dis-
                 played  using  polar  maps  utilizing the bulls  eye  ap-
                 proach with  the apex  located at the centre and the