Page 506 - Clinical Application of Mechanical Ventilation
P. 506

472    Chapter 14



                        Removal of airway foreign   While some believe that the rigid bronchoscope is useful in such 
                     TREATMENT                        means of employing a variety of grasping forceps. Foreign bod-
                          bodies
                                                      cases, it is possible to remove almost all airway foreign bodies by 
                                                      ies removal in this way include gold crowns, peanuts (frequent in 
                                                      children), paper clips, drug containers, and fishbone.

                        Electrosurgical treatment   Joule heat caused by the electrosurgical current evaporates cells 
                                                      for incision and coagulation. Can be used for much of the same 
                                                      cases as Lasers, and treatment capability is expanded with the 
                                                      variety of accessories.
                      Courtesy of Olympus America Inc.
                                            airway, (2) removal of foreign bodies (common in pediatric patients), (3) removal of
                          An example of     endobronchial tissues, (4) intubation of difficult airway and (5) drainage of an abscess.
                        therapeutic uses of fiberoptic
                        bronchoscopy is the removal   Large foreign objects in the airway are removed by rigid bronchoscope.
                        of secretions, mucus plugs, or
                                            Bronchoscope and Medications
                        polyps in the airway.

                                            The main components of a fiberoptic bronchoscope are the handle and insertion
                                            tube (Figure 14-8). The handle consists of the eyepiece, bending mechanism, and


















                                                    Specifications
                                                                  Field of view        120°
                                                     Optical System
                                                                  Depth of Field        3–50 mm
                                                                  Distal End Outer Diameter ø 6.1 mm

                                                     Insertion Tube  Insertion Tube Outer
                                                                  Diameter            ø 6.2 mm
                                                                  Working Length        550 mm
                                                     Instrument   Channel Inner diameter  ø 3.2 mm
                                                     Channel      Minimum Visible Distance  5 mm
                                                     Bending Section Angulation Range  UP 180°, DOWN 130°
                                                     Total Length                     840 mm

                                                                                              Light Guide
                                                             1808 UP   Instrument                       Image Courtesy of Olympus America Inc.
                                                                        Channel               Objective

                                                              1308 DOWN                       Lens
                                                                                              Light Guide
                                           Figure 14-8  An example of flexible fiberoptic bronchoscope and specifications (Olympus
                                           model BF-XT40).





                        Copyright 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part. Due to electronic rights, some third party content may be suppressed from the eBook and/or eChapter(s).
                      Editorial review has deemed that any suppressed content does not materially affect the overall learning experience. Cengage Learning reserves the right to remove additional content at any time if subsequent rights restrictions require it.
   501   502   503   504   505   506   507   508   509   510   511