Page 1288 - Clinical Immunology_ Principles and Practice ( PDFDrive )
P. 1288

1250         Part ElEvEn  Diagnostic Immunology


        the antigen-specific response will find many more applications   5.  Ward M, Turner P, DeJohn M, et al. Fundamentals of acoustic cytometry.
        and will lead to new discoveries and a reassessment of certain   Curr Protoc Cytom 2009;49:1.22.21–21.22.12.
        existing concepts. 56                                   6.  Chattopadhyay PK, Hogerkorp CM, Roederer M. A chromatic explosion:
                                                                  the development and future of multiparameter flow cytometry.
                                                                  Immunology 2008;125:441–9.
        CONCLUSIONS                                             7.  Perfetto SP, Chattopadhyay PK, Roederer M. Seventeen-colour flow
                                                                  cytometry: unravelling the immune system. Nat Rev Immunol
                                                                  2004;4:648–55.
            On tHE HOrIZOn                                      8.  Giepmans BN, Adams SR, Ellisman MH, et al. The fluorescent toolbox
                                                                  for assessing protein location and function. Science 2006;312:217–24.
          •  The combination of flow cytometry and mass spectrometry expands   9.  Chattopadhyay PK, Yu J, Roederer M. Application of quantum dots to
           the number of cell markers analyzed simultaneously (≥35 currently   multicolor flow cytometry. Methods Mol Biol 2007;374:175–84.
           performed), including extracellular and intracellular targets to provide   10.  Rabinovitch PS, June CH, Kavanagh TJ. Introduction to functional cell
           an extensive evaluation of functional markers.
          •  Flow cytometry utilizing spectral rather than conventional light analysis   assays. Ann N Y Acad Sci 1993;677:252–64.
           has the potential to allow more “colors” to be accurately evaluated   11.  Vowells SJ, Sekhsaria S, Malech HL, et al. Flow cytometric analysis of the
           without the need for complex compensation schemes to handle the   granulocyte respiratory burst: a comparison study of fluorescent probes. J
           overlapping light emissions from conventional fluorochromes. This   Immunol Methods 1995;178:89–97.
           could facilitate more extensive polychromatic studies to be performed   12.  Darzynkiewicz Z, Halicka HD, Zhao H. Analysis of cellular DNA content
           easily in the clinical laboratory.                     by flow and laser scanning cytometry. Adv Exp Med Biol
                                                                  2010;676:137–47.
                                                               13.  Loken MR, Brosnan JM, Bach BA, et al. Establishing optimal lymphocyte
        Flow cytometry has become readily available in clinical labora-  gates for immunophenotyping by flow cytometry. Cytometry
        tories, and the application of this technology has moved forward   1990;11:453–9.
        along with significant improvements in instrumentation and   14.  US Clinical and Laboratory Standards Institute. Clinical applications
        the availability of an array of monoclonal reagents. Properly   of flow cytometry: quality assurance and immunophenotyping of
        performed,  flow  cytometry  can  provide  rapid  and  accurate   peripheral blood lymphocytes. Villanova, PA: NCCLS Publication H24-T;
                                                                  1992.
        lymphocyte subpopulation identification. The primary clinical   15.  Stewart CC, Stewart SJ. Multiparameter data acquisition and analysis of
        indications of immunophenotyping remain quantifying CD4   leukocytes. Methods Mol Biol 2004;263:45–66.
        T-cell counts in HIV infection, lineage assignment in leukemias   16.  Parks DR, Roederer M, Moore WA. A new “Logicle” display method
        and lymphomas, evaluation of other hematological cell types,   avoids deceptive effects of logarithmic scaling for low signals and
        and assessment of CD34 expression to identify stem cells for   compensated data. Cytometry A 2006;69:541–51.
        transplantation.  Additional uses include characterization of   17.  Roederer M, Moody MA. Polychromatic plots: graphical display of
        immune deficiency disorders, evaluation of immune-mediated   multidimensional data. Cytometry A 2008;73:868–74.
        inflammatory diseases, and assessment of patients after organ   18.  Roederer M. Spectral compensation for flow cytometry: visualization
        transplantation. Generally, immunophenotyping does not    artifacts, limitations, and caveats. Cytometry 2001;45:194–205.
        represent a diagnostic procedure but, rather, plays a part in the   19.  Owens MA, Vall HG, Hurley AA, et al. Validation and quality control of
        evaluation  and  understanding  of  complex  disorders  and  the   immunophenotyping in clinical flow cytometry. J Immunol Methods
                                                                  2000;243:33–50.
        longitudinal evaluation of immunomodulatory therapy.   20.  Schwartz A, Marti GE, Poon R, et al. Standardizing flow cytometry: a
           It is critical to recognize that immunophenotyping is a means   classification system of fluorescence standards used for flow cytometry.
        of  identifying  cells  but  is not  directed at  cell  function. The   Cytometry 1998;33:106–14.
        expansion of flow-cytometric techniques to evaluate intracellular   21.  Yamada M, Tamura N, Shirai T, et al. Flow cytometric analysis of
        characteristics, assess intracellular changes associated with activa-  lymphocyte subsets in the bronchoalveolar lavage fluid and peripheral
        tion, characterize apoptosis, and identify antigen-specific T cells   blood of healthy volunteers. Scand J Immunol 1986;24:559–65.
        has moved this technology into the cell function arena. These   22.  Reichert T, DeBruyere M, Deneys V, et al. Lymphocyte subset reference
        newer approaches expand the utility of flow cytometry as a   ranges in adult Caucasians. Clin Immunol Immunopathol
        valuable method for the characterization of various aspects of   1991;60:190–208.
        immune function.                                       23.  Shearer WT, Rosenblatt HM, Gelman RS, et al. Lymphocyte subsets in
                                                                  healthy children from birth through 18 years of age: the Pediatric AIDS
                                                                  Clinical Trials Group P1009 study. J Allergy Clin Immunol
        Please check your eBook at https://expertconsult.inkling.com/   2003;112:973–80.
        for self-assessment questions. See inside cover for registration   24.  Levi FA, Canon C, Touitou Y, et al. Seasonal modulation of the circadian
        details.                                                  time structure of circulating T and natural killer lymphocyte subsets
                                                                  from healthy subjects. J Clin Invest 1988;81:407–13.
                                                               25.  Fleisher TA, Oliveira JB. Autoimmune lymphoproliferative syndrome. Isr
        REFERENCES                                                Med Assoc J 2005;7:758–61.
                                                               26.  Yarchoan R, Venzon DJ, Pluda JM, et al. CD4 count and the risk for death
         1.  Shapiro HM. How flow cytometers work. 4th ed. Hoboken, NJ: Wiley;   in patients infected with HIV receiving antiretroviral therapy. Ann Intern
           2003.                                                  Med 1991;115:184–9.
         2.  Kachel V. Hydrodynamic properties of flow cytometry instruments. New   27.  Sekhsaria S, Fleisher TA, Vowells S, et al. Granulocyte colony-stimulating
           York: Wiley Liss; 1990.                                factor recruitment of CD34+ progenitors to peripheral blood: impaired
         3.  Thompson JM, Gralow JR, Levy R, et al. The optimal application of   mobilization in chronic granulomatous disease and adenosine
           forward and ninety-degree light scatter in flow cytometry for the gating   deaminase—deficient severe combined immunodeficiency disease
           of mononuclear cells. Cytometry 1985;6:401–6.          patients. Blood 1996;88:1104–12.
         4.  Goddard G, Martin JC, Graves SW, et al. Ultrasonic   28.  Oliveira JB, Notarangelo LD, Fleisher TA. Applications of flow cytometry
           particle-concentration for sheathless focusing of particles for analysis in a   for the study of primary immune deficiencies. Curr Opin Allergy Clin
           flow cytometer. Cytometry A 2006;69:66–74.             Immunol 2008;8:499–509.
   1283   1284   1285   1286   1287   1288   1289   1290   1291   1292   1293