Page 149 - bukuneutron
P. 149

tion 6.7.

           X1 = d1  (6.7)
           X2 d2

    Where X1,X2,d1 and d1 are the dose or dose rate
at distance d1 and at distance d2 respectively from the
radiation source. Dose at distance d2 is predetermined
value according to the radiation protection personnel,
so the actual value d2 which determine the border be-
tween zone 1 and zone 2 can be established.

    Each zone has to be clearly designated by using ra-
diation sign with the information of radiation level, type
of radiation, the strength of radiation source and con-
tact information of responsible personnel. Legal ion-
ization radiation hazard sign is described by the black
radiating three blade with the circle is the radioactive
source lay on the background given in yellow color.
The legal system indicate the zone category is shown
in Figure 6.8

    This figure shows that one of the blade has point-
ing down, which is different compared to other legal
practises. The geometry of the ionizing radiation sign
should follow the guideline stated by the regulatory body,
the dimension is proportional to the circle diameter, D,
at the center. The similar ionizing radiation sign is used
to describe the presence of radioactive materials emit
radiation does not matter whether it is γ, β, α, X-ray or
neutron.