Page 85 - belden
P. 85

I N DUS T R I A L  A U T O M A TI O N  & P R O C E S S C O NTRO L C A B L E S                       85

               UL Instrumentation Cable (continued)
               600V Tray Cables
                                                                                                                          Industrial Cable
               18 AWG Pairs
                                                  • UL TC                            • NEC: NPLF
                                                  •  UL Sunlight Res                 •  ICEA S-73-532, S-61-402, T-29-520
                                                  • Oil Res                          • FT4
                                                  • Direct Burial                    • IEEE 1202/383

                                               Pull Tension   Bend Radius (Min)    OD (Nom)          Jacket Thickness
                  Part No.   Pairs    Color Code  (Max)
                                                  Lbs       Inch      mm        Inch      mm        Inch      mm

                                  ®
               18 AWG • Individually Beldfoil  Shielded Pairs + Overall Beldfoil Shielding
                 Stranded (7 x 26) BC Conductors • PVC/Nylon Insulation • PVC Jacket
                   1048A      2         E1        140       3.80     96.52      .381      9.68      .048      1.22
                   1049A      4         E1        258       4.90     124.46     .489     12.42      .053      1.35
                   1050A      8         E1        350       6.60     167.64     .654     16.61
                                                                                                    .064      1.63
                   1051A      12        E1        728       7.90     200.66     .785     19.94
                   1052A      16        E1        963       9.00     228.60     .898     22.81
                   1053A      24        E1       1434      11.10     281.94    1.115     28.32
                                                                                                    .084      2.13
                   1054A      36        E1       2139      13.00     330.20    1.299     32.99
                   1038A      50        E1       2962      15.30     388.62    1.527     38.79
               18 AWG • Overall Beldfoil Shielding • Exposed Run • Green Insulated Ground Wire
                 Stranded (7 x 26) BC Conductors • PVC/Nylon Insulation • PVC Jacket
                  3088AE      1         E1        80        3.40     86.36      .340      8.64      .048      1.22
                 Stranded (7 x 26) BC Conductors • Cross-Linked Poly Insulation • PVC Jacket
                  3088CE      1         E1        63        2.75     69.85      .276      7.01      .048      1.22
































                        To Specify Conductor, Insulation and Jacket Options:  Conductor     Conductor
                                                                             Insulation/Jacket          Insulation/Jacket
                        1234               A           E         Bare  Tinned             Bare  Tinned
                                       Add or Modify for         A     B      PVC-Nylon/PVC  S   T      XLP/Haloarrest ®
                       Start with    Conductor, Insulation,    Add for Exposed
                      Base Part No.     and Jacket.    Run Rating  C   D       XLP/PVC     U     V    XLP/HaloarrestXLink ™ -1
                 (1000 and 3000 Series Cables Only)
                                      See table at right.        G     H       XLP/TPE     W     X    XLP/HaloarrestXLink-2
                                                                                                      XLP/HaloarrestXLink-2,
                                                                 Q     R       XLP/CPE     Y     Z
                                                                                                        Marine Approved
               BC = Bare Copper • CPE = Chlorinated Polyethylene • XLP = Cross-Linked Poly

                                   Fo r  m o r e  i n fo r m at i o n,  c o n t a c t   Be ld e n  Te ch n i ca l  S u ppo r t :   1- 8 0 0 - B E L D E N -1  •  www. b e l d e n . c o m
   80   81   82   83   84   85   86   87   88   89   90