Page 219 - belden
P. 219

PA I R E D  C A B L E S                                                                            219

               Computer Cables for RS-232 Applications




                                        ®
               300V 80°C • Overall Beldfoil  Shield
                                                                                     • NEC: CMG
                                                                                     • CEC: CMG FT4








                                                Insulation    Jacket        Capacitance
                            Color    OD (Nom)
                 Part No.  Pairs                Thickness  Thickness  Cond. - Cond.  Cond. - Shield  Additional Features/Ratings
                            Code
                                   Inch  mm   Inch  mm    Inch  mm   pF/Ft  pF/m  pF/Ft  pF/m
               24 AWG • SR-PVC/PVC
                 Stranded (7 x 32) TC Conductors • Semi-Rigid PVC Insulation • Overall Beldfoil Shielding • 24 AWG TC Drain Wire • Chrome PVC Jacket
                 9501   1   Chart 3  .156  3.96  .011  .28  .032  .81  40   131   74   233
                 9502   2   Chart 3  .222  5.64
                 9503   3   Chart 3  .232  5.89
                 9504   4   Chart 3  .265  6.73
                 9505   5   Chart 3  .289  7.34
                                              .011  .28   .032  .81                                UL AWM Style 2464
                 9506   6   Chart  3  .289  7.34
                                                                                                    CSA AWM I A
                 9507   7   Chart  3  .294  7.47                                                    MSHA* (9502)
                                                                                                 75 Ω Nominal Impedance
                 9508   8   Chart  3  .324  8.23                      30    98    50   164        60%Velocity of Prop.
                                                                                            Conductor DCR (Nom): 24.0/1000’ (78.7 Ω/km)
                 9509   9   Chart 3  .334  8.48
                                                                                            Shield DCR (Nom): 18.0 Ω/1000’ (59.1 Ω/km)
                 9510   10  Chart 3  .368  9.34
                 9515   15  Chart 3  .417  10.6  .011  .28  .034  .86
                 9519   19  Chart 3  .448  11.4
                 9525   25  Chart 3  .503  12.8  .011  .28  .045  1.14
                 9550   50  Chart 3  .708  18.0  .011  .28  .054  1.37
                                                                                                                          Paired Cable
               Plenum • Overall Beldfoil Shield
                                                                                     • NEC: CMP
                                                                                     • CEC: CMP FT6




                                                                                                 Capacitance
                                           OD (Nom)     Insulation Thickness  Jacket Thickness
                  Part No.  Pairs  Color Code                                            Cond. - Cond.   Cond. - Shield
                                         Inch    mm     inch    mm      Inch    mm     pF/Ft   pF/m    pF/Ft   pF/m
               24 AWG • FEP/Flamarrest ®
                  Stranded (7 x 32) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 24 AWG TC Drain Wire • Natural Flamarrest Jacket
                  82641   1     Chart 3  .106    2.69   .006     .15    .014    .36     31      102     59     194
                  82502   2     Chart 3  .162    4.11
                  82503   3     Chart  3  .169   4.29   .006     .15    .014    .36
                  82504   4     Chart  3  .193   4.90                                   25      82      45     148
                  82505   5     Chart  3  .196   4.98   .006     .15    .014    .38
                  82506   6     Chart 3  .209    5.31
                  82509   9     Chart 3  .246    6.25   .006     .15    .015    .38     23      75      42     138

               24 AWG • FEP/FEP
                 Stranded (7 x 32) TC Conductors • FEP Insulation • Overall Beldfoil Shielding • 24 AWG TC Drain Wire • Red FEP Jacket
                  88641   1     Chart 3  .106    2.69   .006     .15    .014    .36     31      102     59     194
                  89503   3     Chart 3  .175    4.45
                  89504   4     Chart 3  .192    4.88   .006     .15    .014    .36     21      69      40     131
                  89505   5     Chart 3  .197    5.00

               TC = Tinned Copper • FEP = Fluorinated Ethylene Propylene • PVC = Polyvinyl Chloride

                                   Fo r  m o r e  i n fo r m at i o n,  c o n t a c t   Be ld e n  Te ch n i ca l  S u ppo r t :   1- 8 0 0 - B E L D E N -1  •  www. b e l d e n . c o m