SECTION 6.0 – INTERIOR WORKS FURNISHING AND OTHER FITTINGS SECTION 6.0 – INTERIOR WORKS FURNISHING AND OTHER FITTINGS
6.6.11 All suspended signages shall be two-sided with a metal frame of 5 mm clear c) External statutory signs shall be coordinated with civil drawings.
acrylic and spray-painted with silkscreen finish or equivalent. The signages’
size shall be not less than 350 mm (height) x 1000 mm (width). Suspended d) Buildings’ label (Blok, Aras dan Ruang).
panel signs shall be hung to slab’s soffit or other approved structure system
using stainless steel rod or cable. e) Buildings’ main directories.
6.6.12 All main internal directories at the lobby area (e.g., diagrammatic plan f) Hospital Organization Board and corporate signage at main lobby
layout/ mimic diagram of the building) shall be of aluminium modular system reception.
and spray-painted with silkscreen finish or sticker cut-out. The signs’ size
shall not be less than 900 mm (height) x 1445 mm (width). g) Internal directional signs at strategic locations.
6.6.13 All internal floor directional signages shall be of a two-sided hanging
aluminium modular system and spray-painted with silkscreen finish or h) Departmental location signs and sub-location signs.
equivalent. The signs’ size shall be not less than 495 mm (height) x 900
mm (width) with minimum font size of 60mm. i) Internal statutory signs (e.g., escape routes).
6.6.14 All signages indicating the building’s floor levels shall be of 4 mm clear j) Door signs, i.e., room titles, numbers, designations, and name slots
acrylic with reverse silkscreen and mirror-cap. The sign’s size shall be not where required (details shall be provided by the Client with the PD’s
less than 200 mm (height) x 330 mm (width). concurrence).
6.6.15 The signage proposal shall fulfil the following concepts: k) M&E signage (shall be coordinated with M&E designs).
a) User and community-friendly. l) Portable signage where required.
b) Enable the public to be familiar with the orientation and directions. m) Notices where required.
c) Sensitive to the needs of the disabled, including the blind and the deaf, n) Room codes (as per architectural drawings) to be fixed on the left of the
as much as possible. top door frames or other suitable locations where there are no doors.
d) The design of signage shall be integrated and enhance the overall o) Floor location directories.
building design.
p) Lift lobby directories.
e) The signages location must reflect the consistency and continuity from
the external environment to the internal environment and easy to read. q) Floor numbers at lift lobbies and staircases where required.
f) Signages placement shall not be too high. The ideal height of signages r) Complex’s identification at the site’s highest point.
may be referred to the JKR Standardised Room Data for Health Facility
document as reference, according to the suitability and type of signages s) Event boards where required.
to be installed.
t) Running digital displays shall be coordinated with M&E designs, where
6.6.16 Where applicable, the types of signage to be provided shall comprise of required.
but not limited to the following:
u) JBPM signage requirements (e.g., fire exit, fire alarm, etc.) shall be
a) Main entrance signage and logo including name of hospital, MOH coordinated with M&E designs.
website and crescent logo; the Client shall provide the details with the
PD’s concurrence. 6.6.17 Pictogram/symbol of international standard and the worded sign shall be
provided where required for immediate impact:
b) External directional signs to be located on roads, parking areas, and
walkways.