Page 96 - JKR HEALTH FACILITY ARCHITECTURAL NEEDS STATEMENT 2021 EDITION_Neat
P. 96

SECTION 6.0 – INTERIOR WORKS FURNISHING AND OTHER FITTINGS   SECTION 6.0 – INTERIOR WORKS FURNISHING AND OTHER FITTINGS



 a)  Cafeteria                       shall be displayed outside of both doors, including the one leading to
 b)  Lift                            the Radiology Room.
 c)  Staircase
 d)  Public Phone                 e)  In the Specialist Clinics, all C/E rooms and related rooms (as stated by
 e)  Male/Female Toilet              the Client) shall be identified with a continuous numbering system. All
 f)   Disable Toilet                 other supporting rooms accessible to the public shall be identified with
 g)  Wash & Dry                      the  same  continuous  numbering  system,  including  individual  rooms’
 h)  Changing Room                   name.
 i)   Prayer Room
 j)   Cleaner’s Room              f)  Numbering  of  the  floors  shall  start with digit 1 (inclusive  of  the
 k)  Breast-Feeding / Nursing / Feeding Room   subterranean floor).
 l)   Nappy Change / Baby Changing / Parenting Room
 m)  Shower                       g)  In  the Operation Theatre Department, all OT  rooms shall have a
 n)  Radiation/Radioactive           continuous numbering system. All doors opening into the OT rooms
 o)  Silence                         shall display the same number of the OT rooms. The same number shall
 p)  No Handphones                   also be displayed at  the end of the  OT’s exit corridor. All other
 q)  No Smoking                      supporting rooms shall be identified with the same number of the OT,
                                     and it is attached to, together with its room name, e.g., Scrub 2 for scrub
 6.6.18   Numbering systems and zoning shall be provided for parking lots.   room to OT number 2.

 6.6.19   Residential units  shall be provided with external directional signs, block   h)  All rooms accessible to the public, patient cubicles, and bays in the
 numbers, unit door numbers, architectural codes, M&E signage (including   Accident and Emergency Department.
 JBPM’s requirements), and letterbox numbers (if required).

 6.6.20    Visual scale shall apply to the signage based on distances, colours used,   i)  Counters such as pharmacy, admission and revenue, registration, and
 and font types. Consideration shall be given to legibility and contrast to aid   others as identified by the Client.
 the visually impaired visitors.
                        6.6.23    The Client’s Charter with an appropriate design and sizes as agreed by the
 6.6.21   Mock-ups of various types of signage shall be submitted for the  PD’s   Client shall be provided for various departments as follows:
 approval before full installation of the said project.
                                                                       Mission     Client’s    Workflow
 6.6.22   Numbering Systems shall be provided for various functions as listed below:   Department   and Vision   Charter   Chart
                                                                       Board
 a)  All patient beds include patient couches where beds with the patients’   Administration   /   /   /
 name-slots shall also be displayed outside the room.   Specialist Clinics             /           /
                                   Central Registration                                /           /
                                                                                                   /
                                                                                       /
                                   Continuing Medical Education
 b)  All multiple  rooms, e.g., Treatment Rooms, Procedure Rooms, C/E   (CME)
 Rooms, and X-ray rooms.           Main Lobby                             /            /           /
                                   Admission/Revenue                                   /           /
 c)  All wards shall be identified by floor/level and zone, using numbers and   Outpatient Pharmacy      /   /
 alphabets. This identification and its specific name shall appear in the   Specialist Office      /   /
 main hospital directory signage in the main lobby, e.g., Wad 3A (Wad   Wards          /           /
 Pediatrik).                       Imaging and Diagnostic                              /           /
                                   All other departments where                         /           /
 d)  All Radiology Rooms and any other clinical rooms with changing   required by the Client except
 cubicles for patients shall have the same continuous numbering   catering and privatised service
 system. The attached changing cubicles’ signages shall be based on
 the same number of the Radiology Rooms and alphabets (e.g., 3A and
 3B for Radiology Room number 3). The signs for these changing rooms